P. 6 Installation Guide
12-Pin Accessories Harness
Wire Colour Function Description
1 BLUE
(–) Trunk /
AUX 3 output
500 mA negative output. This output can be used to control the
trunk release (1-sec. pulse), or it can be set to operate as a
constant output as long as the
TRUNK button is held pressed
(for sunroof or window closure)
2 BROWN
(–) Lock
output
Programmable 500 mA negative output: 1/10-sec., 7/10-sec. or
4-sec. pulse
3 GREEN
(–) Unlock
output
Programmable 500 mA negative output: 1/10-sec., 7/10-sec.,
4-sec. or double 1/4-sec. pulse (
ON 250 ms, OFF 500 ms, ON
250 ms).
4
WHITE /
BROWN
(–) Rearm
output
500 mA ground signal when the doors are locked by remote
control. This wire will go to ground 1/2 sec. before the
LOCK
pulse, and go out 1/8 sec after
LOCK. The wire must be
connected to the OEM arm wire (usually the door pin).
Note: The module will also give a rearm pulse on this wire
when it shuts down the vehicle after a remote start.
5
WHITE /
GREEN
(–) Disarm
output
500 mA ground pulse when the doors are unlocked by remote
control. Connect to the OEM disarm wire of the vehicle.
Note: The system will also give a disarm pulse on this wire
before every remote start.
6
BLUE /
WHITE
(–) AUX 1
output
Depending on the configuration of Mode 3, Function 4 (see
programming options), this output will provide either a
500 mA ground output on the 2
nd
consecutive press of the
UNLOCK button to unlock all doors, or a horn confirmation on
the first or second press of the
LOCK button.
7
WHITE /
ORANGE
(–) Starter kill
output
(armed output)
This wire will provide a constant 500 mA output when the
system is armed (locked by remote control). It can be
connected to an external starter interrupt relay.
This wire should be connected to a single pole double-throw
relay: this wire will connect to pin 85 on the relay, and pin 86
will be connected to the ignition wire.
The starter kill output becomes active during remote starts.
One benefit of the starter kill is the anti-grind feature. Once the
vehicle has been remote started, the anti-grind prevents the
starter motor from re-engaging when the ignition key is
inserted in the ignition switch and accidentally turned to the
CRANK position.
8 ORANGE
(–) AUX 2
output
This negative 500 mA output can be programmed for one of
the following options:
1. Constant while the FUNCTION and LOCK buttons are
pressed + 1 sec after release of the buttons.
2. FUNCTION + LOCK toggles ON / OFF (max. 30 sec.).
3. FUNCTION+ LOCK toggles ON / OFF (max. 4 minutes Æ
Only when running under a remote start).
4. Priority door access (2
nd
press of UNLOCK to unlock all
other doors). Refer to Priority Door section on page 17
for more detail.
Kommentare zu diesen Handbüchern